SYSTEM OPERATION
6-51
System 2 Installation / Programming Manual
CHAPTER 6
SYSTEM OPERATION
Programming Functions
Programming is done through the Keypad and LCD, Video Display Terminal (Corby Part #4100), or Personal
Computer, and menus. Each component is discussed in detail in Chapter 5.
User Functions
Users can gain access through a Keypad, Bar Code, Data Chip, Magnetic Stripe, Proximity or Wiegand Card
Reader. Five possible results can occur when a user enters a code or card. Each one is outlined below and
assumes a user number of 0001:
1) When the valid code for user number 0001 is entered any or all of the programmed outputs will
activate. The valid user number, door, time, and date will be displayed on the LCD:
Valid User 0001 1 hh:mm mm/dd.
2) When a valid code is entered outside the programmed time schedule, the output(s) will not activate.
The following will be displayed on the LCD:
Sched Error 0001 1 hh:mm mm/dd.
3) When a valid code is entered on a port that it does not have permission for, the output(s) will not
activate. The following will be displayed on the LCD:
Door Perm 0001 1 hh:mm mm/dd.
4) When an invalid code is entered, (example shows code 12480 on port one) the output(s) will not
activate. The following will be displayed on the LCD:
Invalid Code 000012480 1 hh:mm mm/dd.
5) When an invalid card is used, (example shows card Facility code 7, card code 12480 on port one)
the output(s) will not activate. The following will be displayed on the LCD:
Inv 712480 1 hh:mm mm/dd.