INSTALLATION
5-25
System 2 Installation / Programming Manual
Wiring Surge Protection
The wire between the transformer and the System 2 should be two conductor, stranded or solid, low voltage
wire of at least 18 AWG. Using a one nanosecond surge protection device installed at the 120VAC outlet, the
wire between the 16.5VAC transformer and the System must be at least ten feet long. The reason is: high
voltage transients travel about one foot per nanosecond. A one nanosecond device will require at least one
nanosecond for it to "start" clamping the surge and in one nanosecond, the destructive voltage has already
traveled one foot towards the System. A ten foot long connection will provide a safe margin. The idea is to
have the clamping action in place before the high voltage gets into the equipment.
Wire
We recommend eight conductor, non-twisted pair with shield, 22 AWG because it's common and generally
available. Plenum cable is available from Corby also. Do not use four pairs of twisted type cable.
Typical wire specifications for Keypads, Card Readers, and Data Chips* is an eight conductor, 22 AWG
stranded multiconductor with overall foil shield and non twisted pair; .032 in. (.81mm) PVC jacket, insulation
thickness .010 in. (.25mm), mutual capacitance per ft. 25-30 pf/ft. 300v, 80 degrees (C), UL style No. 2464,
CSA type SR-PVC. This wire must be multiconductor and not twisted pair. It should be noted that all
multiconductor wire has some overall twist, which is OK to use. The use of any other wire is experimental and
not supported by Corby. Any unused conductors may not be connected to ground or doubled up with active
wires. In some applications where not all features are used a cable with less conductors can be used.
Door Locks and Transformer connections require a two-conductor, 18 gauge wire (most popular is jacketed
multiconductor or twisted pair is also acceptable).
The optional Printer requires a three conductor, shielded cable, and the optional Video Display Terminal or PC
a minimum five conductor, shielded cable. Refer to the Installation Section or Wiring Diagrams for exact wire
connections.
Data Chip wire length can be extended by using a twisted pair for the data and negative wires of the
reader only. This optional method is the exception to the non-twisted rule. See the wiring diagram for
Data Chip readers for more information.
WARNING! Class II wiring practices must prevail as defined by the National Electrical Code. Wiring that
carries AC voltage may not be run in the same conduit or next to DC wiring of the System 2. Depending on
voltages and the actual type cable used, System operation may be a problem in areas with high electrical noise.
It is best to not run wires on or near fluorescent light fixtures.