INSTALLATION
5-47
System 2 Installation / Programming Manual
Printer Baud Rate and Dip Switch Settings
The System 2 outputs serial data at 9600 Baud with 8 data bits, 1 stop bit, and no parity. To set the switches
for the printer turn OFF the AC power to the printer and remove the switch cover located above the serial
connector. Only position 4 should be in the ON position. All other positions must be in the OFF position for
proper operation.
Refer to the Citizen user's manual for additional information.
Connecting To a VDT
You must solder a cable together to make your connections from a VDT to a printer. One end plugs into the
VDTs DB 25 pin connector marked “Modem”. Plug the other end of the data cable into the printer connector
on the right side of the printer. You will need a minimum 5 conductor shielded cable, and a male DB25
connector. The printer and VDT are factory set at 9600 BAUD when shipped with a System 2.
The baud rate may be changed to a lower rate if long cable lengths are required.
The printer baud rate (on the VDT) is not set to 9600 baud. You must configure the VDT’s printer output at
9600 baud.
To activate the AUX port for the printer press CTRL SHIFT PRINT simultaneously. AUX will appear at
the top of the VDT.