QUICKSTART
2-13
System 2 Installation / Programming Manual
Quick Installation
U Remove all power from the unit. AC and standby battery.
U Run the wire. You'll need cables for the Reader or Keypad and Door Ajar switch, and a separate
two conductor for the door lock. Don't forget a pair for the AC power transformer, one for the
door lock power supply, and a wire going to a cold water pipe or electrical box for grounding.
U Mount the Keypad, Card Reader or Data Chip Reader. Keypads should be mounted at eye level.
Be sure if you are mounting a Keypad or Reader outside, that it is a weatherproof model.
U Mount the door lock and FOLLOW THE DIRECTIONS that come with it! Make sure to install a
diode across the coil for noise and spike suppression on DC powered door locks.
U Install the Request-To-Exit button and Door Ajar/Time Cancel switch. Don't run the Request-To-
Exit wires out to the Keypad or Reader. Drop them off inside the protected area.
U Make your connections to the System 2 and power it up.