PC/VDT PROGRAMMING - BATCH ENROLL CARDS
9-221
System 2 Installation / Programming Manual
The VDT will display the instructions:
01 03
Enter Door (0=Done) [__]
The first line of the VDT will display the door(s) this group is allowed to access.
At the Enter Door (0=Done) [ _ _ ] prompt, enter the next door this group is
allowed to access. When you are finished press 0 and ENTER. If you wish to change the door
permission at any time, reenter the number to deny access to a specified door.
Example: If you wish to “take door #3 permission away” from these users, enter door 3 again
and the permission will be denied.
If you select Port #3 and you do not have this System set-up for networking, the VDT will
display:
Error!
Entry Out of Range!
Press Any Key
To enable more than two doors, the Networking Option needs to be installed. Proceed to
Option #13 for installation instructions.
When you are finished entering door numbers press 0.
First Card Number
If you are using Wiegand or Proximity cards, check the back of the cards. There is a label
which gives you the Cards Facility Code and the five digit Card Number. Let’s say for example
your first Card has a Facility Code of 08 and a code of 12345, your First Card Number would be
812345 (the Facility Code and the Card Number), the leading zero will be ignored.
If you are using Bar Code or Magnetic Stripe cards, they do not have a facility code. Simple
enter the five digit code on the back of the card.
At this point, the VDT will display one of the following set of instructions:
If you chose card type 2 (Mag or Bar Code) the VDT will display:
Enter Number
0=Quit
Enter Card [00000_____]
If you chose card type 5 (16 Digit Mag, Bar Code) the VDT will display:
Enter Number
0=Quit
Enter Card [________________]