Zones can be manually excluded as you arm your security system (if they are inoperable or
if they would conflict with a planned activity). To enter Zone Bypass Mode, press + 6 .
The green ‘ready’ LED will blink to indicate bypass mode. Press to scroll upwards to the
desired zone, or enter the zone number (01, 02, 03, etc...). The LED of the selected zone will
light and its status wil be displayed:
Zone Status LED Status
Normal Zone LED + Ready LED
Open Zone LED only
Trouble Zone LED + Trouble LED
Bypass Zone LED + Bypass LED
Press to bypass the selected zone or to remove bypass. After adjusting the zone,
press to move to the next zone or to return to Zone Bypass Mode. Press a
second time to exit Zone Bypass Mode.
Zone bypass is erased every time you disarm. If you bypass zones regularly, ask your
security company about programming Quad Key buttons to automate this process for you.
A PIN number can be required before pressing 6 to bypass zones. Ask your security
company if you would like this feature activated.
[6] Bypassing Zones + 6
#
Clear
#
Clear
[7] Installer Programming
[8] User Programming + 8 + User PIN
This area is for security company use only.
System Users with appropriate authority can set User PINs, system time, auto-armimg
time, and other advanced features in this section. Only User PINs with authority levels 01
and 02 can access this area. See below for instructions regarding User Programming.
[9] No Entry Delay Arming & Utility Output + 9
During the exit delay period, enter + 9 to arm your system without entry delays. All armed
zones will create an alarm instantly. Anyone entering through a protected door will cause an
immediate alarm because the entry delay has been cancelled. This is sometimes used to
increase security after everyone has arrived home for the evening.
If your system is equipped to operate auxilliary devices, such as an electronic or magnetic
door lock, entering + 9 + Utility PIN will activate the device. Ask your security company
for additional information about adding or operating this feature.