[4] Set System Time Clock 4 +
Many important Vision features utilize an internal clock to operate. Set, or reset, the
clock here. Set hours and minutes (HH:MM) using 24 hour format (1330 = 1:30pm) and
press . Then set month and day (MMDD), press , year (YY) and .
[5] AM/PM or 24 Hour Clock 5 +
If your Vision keypad displays the system time clock, you may select AM/PM or 24 hour
display here.
[6] Auto Arm 6 +
Your Vision security system can automatically arm itself at the same time every day. Use
this programming area to control Auto Arming. After pressing 6 and Enter, use the 1 button
to turn Auto Arming On or Off (LED 1 lit for Auto Arm On and off for Auto Arm Off) then enter
an arming time (using 24Hr. format) and press . Press twice to exit programming.
#
Clear
10
Complete sequence to set the system clock
+ 8 + PIN + 4 + + HHMM + + MMDD + + YY +
(#, # to exit programming)
Complete sequence to AM/PM or 24Hr. clock display
+ 8 + PIN + 2 + + days +
(#, # to exit programming)
Complete sequence to set Auto Arming
+ 8 + PIN + 6 + + 1 (to select Auto Arm On or Off) + +
Time (24Hr. format) +
(#, # to exit programming)